Ensuring Data Integrity in the Pharma Space
Whitepaper
Published: July 27, 2023
Compliance with good manufacturing or laboratory practice (GMP or GLP) guidelines can help labs ensure the quality and integrity of biopharmaceutical data.
Poor data management or deliberate falsification can cause integrity breaches, undermine product quality and even result in costly recall events.
While a reliance upon manual and paper-based processes can introduce critical errors, electronic systems offer user-friendly, efficient solutions that can keep your data safe.
This whitepaper explores advanced electronic solutions to streamline your biopharmaceutical workflow and help you stay compliant with the latest regulations.
Download this whitepaper to discover:
• The latest GLP and GMP compliant data management practices
• Common vulnerabilities in data management processes according to ALCOA+ principles
• A laboratory information management system (LIMS) that integrates notebook and execution system workflows
The pharmaceutical industry, together with contract research and contract
manufacturing organizations (CRO and CMO) must work under Good
Manufacturing or Laboratory Practice regulations (GMP or GLP) to ensure the
safety and quality of pharmaceutical products. Compliance with these
mandatory regulations ensures both data quality and data integrity. Over the
past 15 years, there have been many data integrity breaches due either to poor
data management practices, reliance on paper or deliberate data falsification.
In the 1970s when the U.S. GLP and GMP were first issued, records were
mainly paper-based. Since then, increased computerization has resulted in new
regulations and guidance documents that aid interpretation of GMP for the
quality and compliance of computerized data systems. Despite this, most of
the record-keeping is still paper-based and —even when computerized systems
are used — signed printouts can be claimed to be the GMP record.
Other poor data management practices include shared user identities,
testing into compliance, failing to backup electronic records, deletion of
data, poor time synchronization and use of unnumbered blank forms.
Now, regulatory authorities are encouraging pharmaceutical companies
to work electronically to ensure data integrity.
Regulatory Compliance – Electronic Records and
Computerized Systems
When a computerized system is used for automating regulatory work such as laboratory analysis, there are specific regulations that must be met. The oldest of these
is European GMP Annex 11 Computerized Systems which was issued originally
in 1992. It was updated in 2011 to enforce data integrity requirements.1
This regulation
outlines ways to validate the system during implementation and provide further
control mechanisms. To fully understand Annex 11, it is worth reading Chapter 4 on
documentation2
as it expands on good documentation practices and record retention,
which impact computerized systems. Annex 11 can also be supplemented by some
of the approaches for computerized systems outlined in EU GMP Annex 15 on
qualification and validation.3
ADVANCED INFORMATICS SOLUTIONS FOR DIGITAL DATA MANAGEMENT
Data Integrity in the Pharma Space
Data Integrity in the Pharma Space | 1
The U.S. Food and Drug Administration (FDA), has a regulation specific for electronic records
and electronic signatures (21 CFR 11).4
This regulation is applicable to all areas regulated by
the agency such as pharmaceutical development, clinical and manufacturing, but it must be
interpreted by the applicable predicate (pre-existing) regulation such as 21 CFR 211 for GMP.5
Data Integrity and ALCOA+
Although data integrity is implied within the current good practice (GXP) regulations,
regulatory authorities have developed the ALCOA+ (ALCOA plus) criteria for data integrity.
The ALCOA criteria were originally defined by the FDA, before the European Medicines
Agency (EMA)6
added an additional four criteria resulting in ALCOA+. Together, these nine
criteria are important for defining what is meant by the term data integrity and should be
applied to both paper and electronic processes to help identify data vulnerabilities.
The nine criteria and the meaning of each are shown in Table 1. These have been reiterated
in data integrity guidance documents issued by regulatory authorities such as the Medicines
and Healthcare Products Regulatory Agency (MHRA), World Health Organization (WHO),
Pharmaceutical Inspection Cooperation Scheme (PIC/S) and FDA7-10 plus industry bodies
Good Automated Manufacturing Practice Forum (GAMP) Parenteral Drug Association (PDA)
and Active Pharmaceutical Ingredient Committee (APIC].11-14
Table 1: Definition of ALCOA Criteria for Data Integrity
Criterion Meaning
ATTRIBUTABLE • The identity of the person or system who executed an action
or created, modified or deleted data is captured in the record.
• When was the activity performed?
LEGIBLE • All data are readable, understandable, and allow a clear picture
of the sequencing of steps or events in the record so that all
GXP activities conducted can be fully reconstructed by the
people reviewing these records at any point during the records
retention time.
CONTEMPORANEOUS • Data must be recorded at the time they are generated or
observed.
ORIGINAL • Original record: data in the file or format in which it was originally
generated, preserving the integrity (accuracy, completeness,
content and meaning) of the record, e.g. original paper record
of a manual observation, or electronic data file from a computerized system
• True or verified copy: an exact verified copy of an original record
ACCURATE • Data are correct, truthful, valid and reliable with context and
meaning.
• No editing without documented amendments/audit trail entries
by authorized personnel
COMPLETE • All data from an analysis including any data generated before a
problem is observed, data generated after repeating part or all
of the work or reanalysis performed on the sample
Data Integrity in the Pharma Space | 2
Data Integrity in the Pharma Space | 3
Criterion Meaning
CONSISTENT • All elements of the analysis, such as the sequence of events
and follow on data files are date (all processes) and time (when
using an electronic system) stamped in the expected order.
• A system functions in a repeatable manner.
ENDURING • Recorded on authorized media, e.g. laboratory notebooks
and numbered worksheets for which there is accountability or
electronic media proven for the record retention period
AVAILABLE • The complete collection of records can be accessed or retrieved
for review and audit or inspection over the lifetime of the record.
Data Management
These guidance documents imply that the industry should move away from paper, as uncontrolled blank forms9,10,15 are unacceptable and the administrative burden to continue using
and reconciling them is expensive. Therefore, laboratories should automate their processes
and eliminate paper records as much as possible.
Question 12 of the FDA data integrity guidance10 asks when does a record become a
GMP record? A critical part of the answer to this question is:
…. it is not acceptable to store electronic records in a manner that allows for
manipulation without creating a permanent record.
This is an issue with some analytical instruments where data can be stored in temporary
memory until an analyst physically saves or prints the data. This allows multiple attempts
at selecting the “right” result before creating a permanent record.
To avoid this situation, we need to consider an advanced informatics solution.
Figure 1: The Analytical Process from Sampling to Reportable Result Automated by an
Advanced Informatics Application
LIMS Application
LES Workflows
Sample
Management
Sample
Preparation
Instrumental
Analysis
Interpretation
Calculation
of Results
Reporting
Results
ELN Functions
Data Integrity in the Pharma Space | 4
Advanced Informatics Solutions
Some of the typical tasks within a regulated laboratory from sample to reportable result
are shown in Figure 1 and consist of sampling, sample management, sample preparation,
instrumental analysis, data interpretation, calculation of the result and reporting. Of these
tasks, the areas automated by traditional Laboratory Information Management Systems
(LIMS) are:
• Sample management
• Instrument interfacing
• Result transfer from instrument data systems
• Calculation of results
• Reporting
Sample preparation is typically a manual process which produces paper records that a
traditional LIMS does not automate. As such, it is an area where poor record management
practices and even falsification can occur as there is little or no evidence of the original data
record. To overcome this, Laboratory Execution System (LES) workflows can be integrated
into a LIMS to automate a process, eliminate paper and ensure data integrity. For example:
• Within a sample preparation LES workflow, instruments such as pH meters and analytical
balances can be integrated so that data can be sent directly to the LIMS database. This
means that there is no longer any GMP data held in temporary memory. Additionally,
automating the sample preparation workflow eliminates manual data entry by an analyst
and transcription error checking by a reviewer.
• Spreadsheets are another area that are a high regulatory risk as they usually consist of
electronic records (that should be saved but may not be) linked with signed paper printouts.
Using a validated spreadsheet within an Electronic Laboratory Notebook (ELN) environment
permits more compliant spreadsheet use. The ELN provides an audit trail to identify who
made entries and corrections, data can be imported electronically from an LES workflow
if required and paper can be eliminated by electronically signing the completed
spreadsheet report.
An example of a modern LIMS platform with integrated LES and ELN functionality is the
LabVantage LIMS version 8.4. This LIMS provides the majority of workflows required in a
regulated laboratory working in the pharmaceutical and biotechnology industries such as:
• Sample management
• Sample labeling
• Reagent and standard preparation and tracking
• Stability testing
• Instrument calibration and maintenance
• Management by exception
• Incorporation of automatic calculations
• Checks of results against specifications
Note, that this is not an exclusive list of processes and tasks that can be automated by a
LIMS/ELN/LES.
ABOUT LABVANTAGE SOLUTIONS
A recognized leader in enterprise laboratory software solutions, LabVantage Solutions dedicates itself to improving customer outcomes by transforming
data into knowledge. The LabVantage informatics platform is highly configurable, integrated across a common architecture, and 100% browser-based
to support hundreds of concurrent users. Deployed on-premise, via the cloud, or SaaS, it seamlessly interfaces with instruments and other enterprise
systems – enabling true digital transformation. The platform consists of the most modern laboratory information management system (LIMS)
available, integrated electronic laboratory notebook (ELN), laboratory execution system (LES), and scientific data management system (SDMS); and,
for healthcare settings, a laboratory information system (LIS). We support more than 1500 global customer sites in the life sciences, pharmaceutical,
medical device, biobank, food & beverage, consumer packaged goods, oil & gas, genetics/diagnostics, and healthcare industries. Headquartered in
Somerset, NJ., with global offices, LabVantage has, for four decades, offered its comprehensive portfolio of products and services to enable customers
to innovate faster in the R&D cycle, improve manufactured product quality, achieve accurate record-keeping, and comply with regulatory requirements.
For more information, visit www.labvantage.com.
©2020 LabVantage Solutions, Inc. All rights reserved. LabVantage is a registered trademark of LabVantage Solutions, Inc. Other product or service names mentioned herein are the trademarks of their respective owners. 2020-02
LabVantage Solutions, Inc.
265 Davidson Avenue, Suite 220
Somerset, NJ 08873
Phone: +1 (908) 707-4100
www.labvantage.com
LabVantage Pharma is the world’s only pre-validated and pre-configured pharmaceutical
LIMS which has the benefits of reducing deployment time by 75% and cost by 85% compared
to a traditional LIMS implementation.
All these functions within a LIMS/LES/ELN workflow provide regulatory compliance advantages through the technical controls mandated by 21 CFR 11 and EU GMP Annex 11 such as
access controls, authority checks, audit trails and checks of data transfers. There is also the
business benefit of faster analysis as data is acquired directly and not written down for later
manual entry into the LIMS. Furthermore, the major benefit is a faster second person review
as there is only the LIMS electronic records to review.
REFERENCES
1 EudraLex - Volume 4 Good Manufacturing Practice (GMP) Guidelines, Annex 11 Computerized Systems. 2011,
European Commission: Brussels.
2 EudraLex - Volume 4 Good Manufacturing Practice (GMP) Guidelines, Chapter 4 Documentation, E. Commission,
Editor. 2011: Brussels.
3 EudraLex - Volume 4 Good Manufacturing Practice (GMP) Guidelines, Annex 15 Qualification and Validation.
2015, European Commission: Brussels.
4 21 CFR 11 Electronic records; electronic signatures, final rule, in Title 21 1997, Food and Drug Administration:
Washington, DC.
5 21 CFR 211 Current Good Manufacturing Practice for Finished Pharmaceutical Products. 2008, Food and Drug
Administration: Sliver Spring, MD.
6 Reflection paper on expectations for electronic source data and data transcribed to electronic data collection
tools in clinical trials. 2010, European Medicines Agency: London.
7 MHRA GXP Data Integrity Guidance and Definitions. 2018, Medicines and Healthcare products Regulatory
Agency: London.
8 WHO Technical Report Series No.996 Annex 5 Guidance on Good Data and Records Management Practices.
2016, World Health Organization: Geneva.
9 PIC/S PI-041-3 Good Practices for Data Management and Integrity in Regulated GMP / GDP Environments
Draft. 2018, Pharmaceutical Inspection Convention / Pharmaceutical Inspection Cooperation Scheme Geneva.
10 FDA Guidance for Industry Data Integrity and Compliance With Drug CGMP Questions and Answers 2018,
Food and Drug Administration: Silver Spring, MD.
11 GAMP Guide Records and Data Integrity. 2017, Tampa, FL: International Society for Pharmaceutical Engineering.
12 GAMP Good Practice Guide: Data Integrity – Key Concepts. 2018, International Society for Pharmaceutical
Engineering: Tampa, FL.
13 Technical Report 80: Data Integrity Management System for Pharmaceutical Laboratories. 2018, Parenteral
Drug Association (PDA): Bethesda, MD.
14 Practical risk-based guide for managing data integrity, version 1. 2019; Available from: https://apic.cefic.org/pub/
Data_Integrity_Best_Practices_Guide_for_API_FINAL_March-2019.pdf.
15 Inspection of Pharmaceutical Quality Control Laboratories. 1993, Food and Drug Administration: Rockville, MD.
Brought to you by
Download the Whitepaper for FREE Now!
Information you provide will be shared with the sponsors for this content. Technology Networks or its sponsors may contact you to offer you content or products based on your interest in this topic. You may opt-out at any time.