Latest Posters
Poster
Novel Fluidics Microbead Trap/Flow Cell Enhances Speed/Sensitivity of Bead-Based Bioassays Up to 5-Fold
Pacific Northwest National Laboratory (PNNL) has developed a micro/nano particle trap that allows surface-functionalized magnetic or non-magnetic particles to be trapped with subsequent perfusion of sample, reagents and wash solutions, yielding significant (up to 5-fold) improvements in assay speed and sensitivity, while significantly reducing sample matrix effects.
Poster
Utilizing High Speed Photography to Optimize Low Volume Dispensing Conditions
In this study we use high-speed photography as a feedback mechanism for adjusting the Nanodrop instrument dispense settings to improve the positional dispense accuracy of low volume (nanoliter) drops. These same parameters can be investigated, with various fluid classes, to reduce deleterious effects on dispensing performance such as deflected streams, satellite formation, secondary pulses and drop deformation.
Poster
Combined Immune Parameters and X-ray data in Early Prediction of Anti-Tuberculosis Chemotherapy Response
20 tuberculosis (12 slow-responders and 8 fast responders) patients were treated with directly observed short course anti-tuberculosis chemotherapy. Chest X-ray was performed. sICAM-1 and suPAR were measured in serum by ELISA, TNFRs using the luminex technology. General discrimination analysis on selected analytes gave, 91.66% and 87,50% correctly classify fast responders and slow responder respectively. The support vector machine analysis gave 100% correct classification.